Call us: +44 (0)1634 300900 | E-mail: sales@dpie.com

Diamond Point International

MEN Mikro G102 - 3U CompactPCI® Serial Managed Industrial M12 Ethernet Switch with Uplink

Up to 25 Gigabit Ethernet Ports on Rear I/O, -40 to +85°C Qualified

MEN Mikro G102 - 3U cPCI Serial M12 Ethernet Switch
Key Features
3U 8HP CompactPCI® Serial Ethernet Switch
Up to 25 Gigabit Ethernet ports on rear I/O
Or 3 ports on front and up to 22 ports on rear
X-coded M12 front option
29 Gbit/s carrier grade switch matrix
Special switch protocols
EN 50155 class TX compliant (railways)
-40 to +85°C with qualified components

Introduction

The G102 is a fully managed 3U flexible multiport Gigabit Switch, with a 29 GBit/s Switch matrix, implemented as a CompactPCI Serial board. It occupies one system slot or one peripheral slot using a 4 HP front panel with two Gigabit Ethernet ports on RJ45 connectors and one 2.5 Gb SFP cage. Alternatively, the G102 can be supplied with three M12 X-coded connectors on the front panel (for A-coded connectors, see the G101). The new backplane concept for MEN routers and switches allows high flexibility in network applications and management.

High Speed, High Efficiency and Extensive Protocols

The G102 guarantees high speed, high efficiency and an extensive firmware supporting various protocols like security, time synchronicity, stability, as well as for temperature needs. The switch supports EEE (Energy Efficient Ethernet) as a standard on all ports, IEEE1588v2 on ports 1 to 12 and SyncE (synchronous Ethernet) as an option.

Various Connection Possibilities due to Various Port Options

The G102 either features three Ethernet ports on the front and up to 22 ports on the rear, or alternatively all 25 ports on the rear. These include 12 ports with integrated 10/100/1000 Mbit/s copper PHYs. In addition, the G102 features a high performance port with up to 2.5 Gbit/s for a SFP pluggable module to support a high speed uplink.

Increased Reliability Through Built-In Test Mechanisms

The switch is fault tolerant and restores itself on its own: If a link is temporarily unavailable, frames can be sent via backup/redundant links (spanning tree protocol/link aggregation) and no data loss occurs. Its built-in test mechanisms make the G102 an even more reliable component in the communication system.

Rugged and Compliant to Railway Standards

The railway Ethernet switch is specifically designed for rugged mobile communication systems and fully compliant with the EN 50155 railway standard, qualified for a -40 to +85°C operation temperature and ready for coating.

Specification

Main Specification

FunctionTested SFP Types
• CISCO GLC-SX-MM, 1 Gbit/s BASE-SX, 220/500 m, 0 to +70°C
• AVAGO ABR-5710 ALZ, 1 Gbit/s BASE-SX, 250/550 m, -40 to +85°C
• Finisar FTLF8519P3BTL, 1 Gbit/s BASE-SX, 300/500 m, -40 to +85°C
• Finisar FTLF1318P3BTL, 1 Gbit/s BASE-LH, 10 km, -40 to +85°C
• Finisar FTLF1518P1BTL, 1 Gbit/s BASE-ZX, 80 km, -40 to +85°C
• AVAGO ABR-57R5APZ, 4.25 Gbit/s BASE-SX, 300 m @ 2.125 Gbps, -10 to +85°C

Switching Matrix
• Throughput: 29 Gbps / 40 Mpps@64 Bytes per packet
• Max. Mac Address Table Size: 8192
• Switching Algorithm. Store-and-Forward with TCAM support

General Network Support
• IPv4 and IPv6 Forwarding and Management
• IPv6 Ready Logo Phase 2

Ports and Port Control
• Energy Efficient Ethernet (IEEE 802.3az)
• ETH Signal Equalization and Power Control
• Port state (admin), speed, duplex mode and flow control
• Port frame size (Jumbo Frames: 9216 Bytes/Packet max)
• Port status (link monitoring) and statistics (MIB counters)
• Port VeriPHY (cable diagnostics), ActiPHY™ and PerfectReach™
• Inband management (VRAP)

User Configuration Interfaces
• HTTP/HTTPs, Telnet, SSHv2, Console (USB)

Switch Management and Monitoring
OAM
• Link OAM: IEEE 802.3ah
• Flow OAM (ingres, egres): IEEE802.1ag, ITU-T Y.1731 Down-MEP, ITU-T Y.1731 Up-MEP, ITU-T Y.1731 MIP,
• SMAC/DMAC Swap
• OAM Performance Monitoring MEF35 Phase 1
• Redirect back to arrival port debugging feature
SNMP Management v1, v2c, v3 (RFC 1212, 1901-1908, 3411-3418)
SNMP v1 Traps (RFC 1157) with multiple destinations
LLDP (IEEE 802.10AB-2005/LLDP)
TIA 1057 LLDP-MED extensions
CDP (Cisco Discovery Protocol)
RMON Group 1, 2, 3 and 9(RFC 2819)
Syslog (RFC 5424)
sFlow (RFC 3176)
Port and Flow Mirroring (10 Ports max)
Fallback Firmware (Golden Firmware)

Configuration Management
• TFTP (RFC 1350)
• Import/Export via Web-Interface
• Fallback Configuration (Golden Configuration)
• Configuration download and upload: XML and inidustry-standards format

Redundancy and Flow Control
• Static Link Aggregation
• Link Aggregation Protocol (LACP: IEEE 802.3ad)
• Back Pressure Flow Control (IEEE 802.3X)
• Spanning Tree (STP: IEEE 802.1 D)
• Rapid Spanning Tree (RSTP: IEEE 802.1w)
• Multiple Spanning Tree (MSTP: IEEE 802.1s)
• BPDU Restrict and Guard Role (IEEE 802.1w Root Guard)
• Ring and Linear Protection Switching (ITU-T G.8031 and G.8032)
• 1+1 port protection, 1:1 port protection, 1:n port protection
• Connectivity Fault Protection (IEEE 802.1ag/ITU-T Y.1731
• Loop Protection

Filtering
• Unicast, Multicast and Broadcast Traffic/broadcast storm control
• Basic ingres limiter
• Dynamic ARP Inspection (RFC 2132 / MAC address based filtering)
• IP Source Guard (draft-baker-sava-cisco-ip-source-guard-00)
• DHCP Snooping (RFC 2132)
• IP MAC binding
• IP MAC binding dynamic to static

Security
• Static L2 Port Isolation
• Port based RADIUS and internal MAC Authentication (IEEE 802.1X)
• RADIUS accounting (RFC 2866ff)
• Single and Multiple IEEE 802.1X
• VLAN and QOS assignment
• TACACS+ (RFC 1492)
• MAC address flood prevention (MAC address table limitation)
• Web and CLI Authentication
• Switch Access Authorization (15 levels)
• ACLs for filtering, policing and port copy

VLAN
• Max. number of VLANs: 4096
• VLAN Tagging and Trunking (IEEE 802.1Q)
• Supported VLAN Types:
• • Private Static VLAN (RFC 5517)
• • MAC, Protocol, IP-Subnet and Port based VLAN (IEEE 802.1Q)
• • VOICE VLAN (IEEE 802.1Q, IEEE 802.1P)
• VLAN Translation (IEEE 802.3ad)
• GVRP VLAN registration (IEEE 802.1Q)
• Multiple VLAN registration protocol (MVRP: IEEE 8021.1ak)
• Guest VLAN Isolation

Multicast
• Max. number of IGMP Groups: 8.000 for Layer 2 and 8.000 for IPv4/IPv6
• IPv4 Internet Group Management protocol (IGMP) v1, v2, v3
• IPv6 Multicast Listener Protocol (MLD) v1, v2 with flooding suppression and router port handling
• Multicast VLAN registration protocol (MVR)
• IGMP throttling, filtering, proxy and leave proxy
• MRP/GMRP GARP Multicast Registration Protocol (IEEE 802.1ak)

QOS
• Active Priority Queues per Port: 8
• Class of Service (IEEE 802.1p)
• Port and queue egress shaper
• Port and User priority mode
• Input priority mapping (PCP, DEI to QOS, DP level)
• Scheduler Mode (weighted and fair scheduling)
• QOS control list (QCL ID, QCL to QCE mapping)
• QCE mapping based on ETH-Type, VLAN ID, UDP/TCP port range, DiffServ field and Tag priority
• Random early discard (RED)
• Policers: port, service, queue and global/VCAP (ACL)
• DiffServ (RFC 2474) and Tag remarking

DHCP
• DHCP Server (RFC 2131/ 3132)
• DHCP Client (RFC 2131 / 3132)
• DHCP Option 82 (DHCP Relay Agent Information Option)

DNS
• DNS Client (RFC 2136)
• DNS Proxy (RFC 5625)

Synchronization
• NTPv4 Client (RFC 5005)
• IEEE 1588v2 PTP with one-step and two-step clock
• IEEE 1588v2 PTP with redundant masters and timing domains
• IEEE 1588v2 boundary, end-to-end and peer-to-peer clock
• IEEE 1588v2 unicast and multicast support
• Optional Synchronous Ethernet (ITU-T G.8261, G.8262 and G.8264)
• Optional combined SyncE and IEEE 1588v2 solution

Layer 2 Bridging
• IEEE 802.1D Bridge with source source specific multicast filtering
• • auto MAC address learning and aging
• • static MAC addresses
• IEEE 802.10d Provider Bridge (native or translated VLAN Q-in-Q bridging)
• Service enabled Provider Bridge (E-LINE: EPL, EVPL; E-Lan: EP-LAN, EVP-LAN)

Layer 3 support
• Classification of Layer 3 flow (SIP, IP Prot, SProt, DProt)
• DHCP Option 82 relay
• Universal Plug and Play (UPnP)
• IPv4 Unicast static routing

Supervision and Control
• Watchdog
• Temperature monitoring
Interface(s)The following configurations are available:
• RJ45: 12x 1 Gbit/s + 1x 2.5 Gbit/s (2x 1 Gbit/s + 1x 2.5 Gbit/s on front) with "on-the-Fly" SFP detection support (Model: 02G102-02)
• M12: 12x 1 Gbit/s CU Ports (3x 1 Gbit/s M12 on front )(Model: 02G102-03)

Enhancements:
• Gigabit Copper Ethernet line card with 4x 1 Gbps ports, available via RJ45 or M12 connectors at the front panel
• Gigabit Copper Ethernet PHY line card with 4x 1 Gbps ports, available via RJ45 or M12 connectors at the front panel
• Gigabit Ethernet SFP PHY line card with 4x 1 Gbps ports, available via SFP cages at the front panel
• Supports up to 6 line cards, depending on configuration, with optional PoE
Connection(s)Front Interfaces
• Two RJ45 connectors, 1000BASE-T (1 Gbit/s), IEEE802.3 compliant, and one SFP slot, 1000BASE-T (1 Gbit/s), or
• Three M12 X-coded connectors, 1000BASE-T (1 Gbit/s)
• Reset button
• Status LEDs (one board status LED, two Ethernet status LEDs)

Rear Interfaces
• USB: One channel, USB2.0 as a console interface for configuration
• Ethernet: Twelve channels 1000BASE-T (1 Gbit/s)
• Serial GPIO (SGPIO): Compliant with SFF 8485 specification

General

ExpansionCompactPCI® Specification PICMG CPCI-S.0
• System or peripheral slot
ElectricalSupply voltages
• +5V (-5%) to 16 VDC max.
Power consumption
• Max. 16 W
MechanicalDimensions: conforming to CompactPCI® specification for 3U boards, 4 HP
Conformal CoatingConformal coating on request
SoftwareFirmware for configuration and management
TemperatureTemperature range (operation):
• -40°C to +85°C
• Airflow 1.5m/s
Temperature range (storage): -40..+85°C
HumidityRelative humidity range (operation): max. 95% non-condensing
Relative humidity range (storage): max. 95% non-condensing
Weight200 g
VibrationVibration (Function): 1 m/s², 5 Hz to 150 Hz (EN 61373)
Vibration (Lifetime): 7.9 m/s², 5 Hz to 150 Hz (EN 61373)
Shock50 m/s², 30 ms
MTBF692.753 h @ 40°C according to IEC/TR 62380 (RDF2000)
Safety/CertificationFlammability
• UL 94V-0

Electrical Safety
• EN 50155 (Insulation)
• EN 50155 (Voltage)
EMCEN 55022 (radio disturbance)
EN 61000-4-2 (ESD Immunity)
EN 61000-4-4 (burst)
Warranty2 Years
RoHSCompliant

Ordering Details

Board02G102-02
12x 1 Gbit/s + 1x 2.5 Gbit/s (2x 1 Gbit/s + 1x 2.5 Gbit/s on front) with "on-the-Fly" SFP detection support

02G102-03
12x 1 Gbit/s CU Ports (3x 1 Gbit/s X-Coded M12 on front)
AccessoriesN/A