MEN Mikro M22 - 8 Binary Inputs/Outputs
 
  • 8 channels output 0..32 V or
  • 8 channels input 0..32 V
  • 2 A load per channel max.
  • Load on ground
  • Overload and line-break detection
  • Interrupt generation per channel
  • Screw terminal/LED version available
  • Electrical isolation
  • ROHS compliant



Datasheet/Manual:

MEN M22 datasheet in PDF format Datasheet in PDF format
Manual available on request Manual available on request

 

Introduction

The M22 uses intelligent power switches to control a load of 2A per channel. The output state is detected and can be read back. This way, a deactivated output can also be used as an input. When an error occurs, an interrupt can be triggered for each channel. This interrupt is maskable. Overload and overtemperature detection for each channel combined with ESD protection make the M22 nearly indestructible - an ideal choice for sophisticated applications requiring critical process output.

The M22 is based on the M-Module™ ANSI mezzanine standard. It can be used as an I/O extension in any type of bus system, i.e. CPCI, VME or on any type of stand-alone SBC. Appropriate M-Module™ carrier cards in 3U, 6U and other formats are available from MEN or other manufacturers.

 
 

Specification

Outputs:

Output voltage range 0V..32V, depending on load resistance
Output current max. 2A per channel, no derating

Inputs:

Switching voltage 5V typ.
Input current 0.5mA (external switch to ground)

Miscellaneous:

Load on ground
Overload protection using delay circuit
Overheating and short-circuit protection
Overvoltage protection with inductive loads
Line-break detection
Low heat production (< 0.4V loss per switch with all outputs at 2A current)
Interrupt generation for each channel

Peripheral Connections:

Via front panel on a shielded 25-pin D-Sub receptacle connector or
Via screw terminal and LED display
Via carrier board (rear I/O)

M-Module™ Characteristics:

A08, D08, INTA, IDENT

Electrical:

Isolation voltage:

  • 500V DC between isolated side and digital side
  • Voltage between the connector shield and isolated ground is limited to 180V using a varistor; AC coupling between connector shield and isolated ground through 47nF capacitor

Supply voltage/power consumption: +5V (-3%/+5%), 20mA typ.
MTBF according to IEC/TR 62380 (RDF 2000):

  • 908,469h @ 40°C (with D-Sub connector)
  • 894,992h @ 40°C (with screw terminal)

Mechanical:

Dimensions: conforming to M-Module™ Standard
Weight: 56g (with screw terminal), 68g (with D-Sub connector)

Environmental:

Temperature range (operation):

  • 0°C to +60°C
  • Industrial temperature range on request
  • Airflow: min. 10m³/h

Temperature range (storage): -40 to +85°C
Relative humidity range (operation): max. 95% non-condensing
Relative humidity range (storage): max. 95% non-condensing
Altitude: -300m to + 3,000m
Shock: 15g/11ms
Bump: 10g/16ms
Vibration (sinusoidal): 2g/10 to 150Hz
Conformal coating on request

Safety:

PCB manufactured with a flammability rating of 94V-0 by UL recognized manufacturers

EMC:

Tested according to EN 55022 (radio disturbance), IEC1000-4-2 (ESD) and IEC1000-4-4 (burst)

Software Support:

MEN Driver Interface System (MDIS™ for Windows®, Linux, VxWorks®, QNX®, OS-9®)

ROHS Status:

This product is lead free/ROHS compliant.


Ordering Details:

Board:

04M022-03 8 binary source inputs/outputs, with D-Sub connector, 0 to +60°C
04M022-04 8 binary source inputs/outputs, with screw terminal, 0 to +60°C

Accessories:

05M000-00 M-Module cable, 2m, with 25-pin D-Sub plug/housing to pig tail
05M000-17 25 mounting screw sets to fix M-Modules on carrier boards

Further Information:

Want further information or pricing on this product? Either fill out our feedback form or contact us for further information.

 
© 2012 Diamond Point International. All rights reserved.