Sitemap - Print Page - Email Link - |
|
|
MEN Mikro M671-Channel Digital Oscilloscope M-Moduleanalog voltage input 40 MS/s 0 to +60°C operation |
![]() |
Datasheet/Manual:
|
|
IntroductionThe M67 is a board for acquisition of analog signals with a bandwidth of up to 10MHz at a maximum resolution of 12 bits and a sampling frequency of up to 40MHz. Variable trigger functions allow application of the M67 as a "digital storage oscilloscope" for measurement and analysis applications. The sampling data is stored in an onboard memory buffer. After the sampling procedure this buffer can be processed by an external host. Individual signal conditioning is made by the customer using a blank prototype PCB that is plugged directly on M67 and must be ordered separately. MEN can produce individual adapters on request. The M67 is based on the M-Module™ ANSI mezzanine standard. It can be used as an I/O extension in any type of bus system, i.e. CPCI, VME or on any type of stand-alone SBC. Appropriate M-Module™ carrier cards in 3U, 6U and other formats are available from MEN or other manufacturers. |
Specification |
|
Analog Input: |
±1V max. input range, 75 Ohm |
Trigger: |
Trigger at signal level, external signal or via software |
Clock: |
Internal or external clock, max. 40MHz |
Buffer: |
4MB |
A/D Conversion: |
12 bits, 40MSPS |
Recording: |
12 ADC bits and 4 external binary inputs |
Binary Inputs/Outputs: |
4 inputs |
Peripheral Connections: |
Via front panel on a shielded combined 15-pin D-Sub receptacle connector |
M-Module™ Characteristics: |
A08, D16, D32, INTA, DMA, IDENT, TRIGI |
Electrical: |
Isolation voltage: 500V DC
MTBF: tbd. (derived from MIL-HDBK-217F) |
Mechanical: |
Dimensions: conforming to M-Module™ Standard |
Environmental: |
Temperature range (operation):
Temperature range (storage): -40 to +85°C |
Safety: |
PCB manufactured with a flammability rating of 94V-0 by
UL recognized manufacturers |
EMC: |
Tested according to EN 55022 (radio disturbance), IEC1000-4-2 (ESD) and IEC1000-4-4 (burst) |
Software Support: |
MEN Driver Interface System (MDIS™ for Windows®, Linux,
VxWorks®, QNX®, OS-9®) |
ROHS Status: |
This product is lead free/ROHS compliant. |
| Ordering Details: | |
Board: |
04M067-00 Digital oscilloscope, 0 to +60°C |
Accessories: |
05M000-17 25 mounting screw sets to fix M-Modules on
carrier boards |
Further Information: |
Want further information or pricing on this product? Either fill out our feedback form or contact us for further information. |
Home - About Us - Contact - Exhibitions - Feedback - News/Press Releases - Ordering - Products - RSS Feed - Support |
© 2012 Diamond Point International. All rights reserved. |