MEN Mikro PU20 - 3U compactPCI 6 HP Wide-Range PSU, 24 to 110 VDC, 120 W

H15 Rear Connector, for Railway Systems, -40 to +85°C Qualified

MEN Mikro PU20 - 3U cPCI 6 HP PSU, 24 to 110 VDC, 120 W
Key Features
19" rack mountable (VMEbus, CompactPCI®)
3U, 6 HP, conformal coating
Auto input voltage range for 24, 72, 110 VDC
Output power 120 W without derating
Holdup time 10 ms according to Class S2
H15 rear connector, fully S-9401 compliant
-40 to +85 °C with qualified components
Prepared for EN 50155 & SIL

Introduction

MEN Mikro's PU20 is a plug-in power supply unit for 19" systems (like VMEbus and CompactPCI® Serial). It is especially designed for computer systems in public transport vehicles and for harsh environments, like railway applications, making it suitable for both onboard and wayside use.

The PU20 has a nominal input power range of 24 V to 110 V with a max. input voltage range of 14.6 to 156 VDC (according to EN 50155 and S-9401). It also has an automatic input voltage range detection for 24, 72, 110 VDC, to define the under-voltage level. Additionally, the PU20 has a configurable voltage range for 36, 48, 74, 96 VDC, which is controlled by a rotary switch.

The standard output voltage is 5 V with a dynamic load sharing of between 12 and 5 V with 120 W. The output power at 3.3 V is 35 W, which is shared with the 5 V load. Switch-on behavior is independent of the load.

The PU20 also has a standby voltage of 5 V with 5W to supply the independent shelf controller, and to support wake-on-LAN functionality.

The PSU provides three ports, on the secondary side, for switching the output voltages. They also indicate the event of an input power failure, output voltage failure or a fail-over temperature.

The PSU is coated conformally, and all components are secured against vibration. When more power supplies run in parallel, the performance loss is shared evenly and, in case of a fault in one of the power supplies, the output power is removed completely so as to avoid any negative effects. The double power monitoring ensures that the output voltage is within the valid range. In case of error, the voltage is powered-down as prepared by the SIL applications. The thermal stress is extremely low due to integrated heat sinks, and diversion of dissipated heat over the mounting surface.

The PU20 is fully prepared for EN 50155 compliance (March 2015), meeting all shock, vibration, EMC and isolation requirements. Operating under temperatures ranging from -40 to 70°C with increments to 85°C for 10 minutes (class TX), with a hold up time of 10 ms, as is in accordance with EN 50155 Class 2.

Specification

Power Supply

InputNominal voltage input: 24 V, 36 V, 48 V, 72 V, 96 V, 110 V (according to EN50155)
• Max. input power range of 14.6..156 VDC
• Automatic input voltage range detection for 24, 72, 110 VDC
• Configurable voltage range for 36, 48, 74, 96 VDC
• Power-on/-off threshold

Input voltage range
• Nominal input voltage of 74 VDC provided (according to S-9401)
• Voltage range for 74 VDC is 20..130 VDC

Power Variations
• No functional disturbance with input voltage variations of 0.6 x Un < 1.4 x Un for 0.1 s
• No functional disturbance with input voltage variations of 1.25 x Un < 1.4 Un for 1 s

Inrush current limiting
Type H15, DIN 41612 plug connector (rear)
Output(s)Output voltages: 12 VDC, 5 VDC and 3.3 VDC

Standby output voltage: 5 VDC with a 5 W load

Accuracy:
• +3.3V (-1%/+3% of the nominal value)
• +5V (-1%/+2% of the nominal value)
• +12V (-3%/+4% of the nominal value)
• +5VSB (-1%/+2% of the nominal value)

Holdup time: 10 ms according to Class S2

Dynamic load distribution
• 120 W for complete temperature range without forced airflow
• Load sharing between 12 VDC output and 5 VDC output, including 3.3 VDC
Type H15, DIN 41612 plug connector (rear)
IsolationIsolation (according to EN 50155)
• Input/output: 3100 VAC
• Input/shield: 3100 VAC
• Output/shield: 1000 VAC
OtherControl and Status Indicator: Three ports on secondary side
• Switches output voltages
• Indicates input power failure, output voltage failure or fail-over temperature

Up to six power supply units can be used in parallel
• Extends availability (backup protection against faults)
• Extends power
• Increases performance
• Ensures redundancy

Overload and short circuit protection
Standby voltage at power down, always available
Reverse polarity protection for input voltage and short circuit
Output voltage and temperature supervision
Overtemperature and overvoltage shutdown

General

ElectricalSee above
MechanicalDimensions: 3U, 6HP
Integrated heat sink
Conformal CoatingAs standard
TemperatureTemperature range (operation): -40..+70°C (85°C/10 mins), no derating
Temperature range (storage): -50..+85°C
Temperature: 70°C, with up to 85°C for 10 minutes according to class Tx (EN 50155)
Airflow: Convection cooling
Cooling test according to EN 60068-2-1
Dry heat test according to EN 60068-2-2
Weight630 g
VibrationVibration (function): 2.02 m/s², 5 Hz - 200 Hz (EN 61373)
Vibration (lifetime): 11.44 m/s², 5 Hz - 200 Hz (EN 61373)
Shock50 m/s², 30 ms (EN 61373)
MTBFmin. 600 000h @ 40°C according to IEC/TR 62380 (RDF 2000)
Safety/CertificationFlammability
• PCB manufactured with a flammability rating of 94V-0 by UL recognized manufacturers

Electrical Safety
• EN 60950-1
• Insulation measurement test according to EN 50155 (12.2.9.1)
• Voltage withstand test according to EN 50155 (12.2.9.2)
EMCEMC Emission:
• EN 55022: CISPR 22 - Class B
• FCC 15.109 and S-9401
EMC Immunity: EN 55024 - Class A

EN 55011 (radio disturbance)
IEC 61000-4-2 (ESD)
IEC 61000-4-3 (electromagnetic field immunity)
IEC 61000-4-4 (burst)
IEC 61000-4-5 (surge)
IEC 61000-4-6 (conducted disturbances)
Warranty2 Years
RoHSCompliant

Ordering Details

Board17PU20-00
120 W, 3U 6HP PSU, wide range input 24 to 110 VDC,24 VDC nom., output 12, 5 and 3.3 VDC, -40 to +85°C with qualified components, conformal coating